-40%

12V 24V DC Refrigeration Compressor Fridge Freezer Marine Solar QDZH35G R134a

$ 68.63

Availability: 80 in stock
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • MPN: QDZH35G
  • All returns accepted: Returns Accepted
  • California Prop 65 Warning: EXAMPLE: Don't fill R134A into a fridge designed for R600A, you will lose 50% of the cooling efficiency due to capillary tube size!
  • Condition: New
  • Model: 12V / 24V DC
  • Type: Compressor
  • UPC: Does not apply
  • Country/Region of Manufacture: China
  • Item must be returned within: 30 Days
  • Brand: Sikelan

    Description

    READ CAREFULLY ALL LISTING BEFORE BUYING!!!!!
    This listing is for a Brand New, Model QDZH35G, 12V / 24V DC (Air Cooling) Compressor, R134a refrigerant, 55 - 95w, Refrigerator Fridge Freezer Marine Boat or for Solar Off Grid.
    Direct low cost replacement for Danfoss BD35 DC compressors
    Suitable for water dispenser, small refrigerator, small freezer, wine cellar and other small cooling appliances used for car, ship and camping.
    Electronic controller INCLUDED with purchase of compressor (like on picture)
    Electronic controller AVAILABLE as spare parts in my store
    Perfect for AC to 12-24DC fridge conversion on R134A , this gas is inert and non-flammable so this is first choice for Boats and mobiles applications
    Choose right compressor size and gas, Send me a message if you need help with that!
    Model NO.: QDZH35G
    Refrigeration Temperature Scope: -18?~10?
    Shape: Cabinet Type (Open Outward)
    Power Supply Type: DC
    Type: Compressor Car Refrigerator
    Voltage: 12V / 24V
    Certification: CE
    1) QDZH35G, DC series, use R134A refrigerant;
    2) Voltage application 12V and 24V;
    3) Cooling type: ST or FAN;
    4) Application: Low Back Pressure, Middle Back Pressure;
    5) Max cooling capacity 100W
    6) power consumption in watt is 17 to 78w depends on rpm setting and back-pressure inside system
    Model
    Displacement (cm3)
    Rotate Speed       (rpm)
    Capacity  (W)
    COP
    EER
    Oil charge
    Cooling Type
    Power Supply
    Certificate
    -23.3ºC (ASHRAE)
    W
    Kcal/h
    Btu/h
    W/W
    Btu/W.h
    ml
    QDZH35G
    3.5
    2000
    60.0
    51.9
    204.6
    1.08
    3.68
    160
    FC
    12/24V
    (DC)
    CE
    2500
    73.0
    63.1
    248.9
    1.07
    3.65
    3000
    86.0
    74.4
    293.2
    1.06
    3.62
    3500
    100.0
    0.00
    86.5
    341.0
    1.05
    3.58
    DIMENSIONS
    :
    WIRING
    :
    Installation(Fig.1)
    Connect the terminal plug from the electronic unit to the compressor terminal. Mount the electronic unit
    on the compressor by snapping the cover over the screw head(1).
    Power supply(Fig.1)
    The electronic unit must always be connected directly to the battery poles (2). Connect the plus to + and
    the minus to -, otherwise the electronic unit
    will not work. The electronic unit is protected against reverse battery protection of the
    installation, a fuse (3) must be mounted in the + cable as close to the battery as possible. 15A fuse for
    12V and 7.5A fuse for 24V circuits are a main switch (4) is used, it should be rated to a
    current of min. 20A. The wire dimensions in Table. 2 must be observed. Avoid extra junctions in the
    power supply system to prevent voltage drop from affecting the battery protection setting.
    Battery protection(Fig.1)
    The compressor is stopped and re-started again according to the decided voltage limits measured on the
    + and - terminals of the
    electronic unit. The standard settings for 12V and 24V power supply systems
    appear from Table. 3. Other settings (Table. 1) are optional if a connection which includes a resistor (9)
    is established between terminals C and P.
    Thermostat(Fig.1)
    The thermostat (7) is connected between the terminals C and T. Without any resistor in the control circuit,
    the compressor with electronic unit
    will run with a fixed speed of 2,000rpm when the thermostat is
    switched on. Other fixed compressor speeds in the range between 2,000 and 3,500 rpm can be obtained
    when a resistor (8) is installed to adjust the voltage (v) of the control circuit. Resistor values for various
    motor speeds appear from Table. 4.
    Fan(optional,Fig.1)
    A fan (5) can be connected between the terminals + and F. Connect the plus to + and the minus to F.
    Since the output voltage between the terminals + and F is always regulated to 12V,a 12V fan must be
    used for both 12V and 24V power supply fan output can supply a continuous current of
    0.5A avg . A higher current draw is allowed for 2 seconds during start.
    LED(optional,Fig.1)
    A 10mA light emitting diode(LED)(6) can be connected between the terminals + and D. In case the
    electronic unit records an operational error, the diode will flash a number of times. The number of flashes
    depends on what kind of operational error was recorded. Each flash will last 1/5 second. After the actual
    number of flashes there will be a delay with no flashes, so that the sequence for each error recording is
    repeated every 3 minutes
    ---------------------------------------------------------------------------------------------
    I always carefully pack items with care to avoid damage during shipping.
    If item is undeliverable because of buyer's wrong, refused, unclaimed or incomplete address. Buyer pays return shipping cost to Seller (Both Original Shipping AND RETURN SHIPPING).
    Buyer is responsible for his import charges and fees if occurs.
    Feel free to contact me for any questions!
    Thanks